Cancer Research Targets  Jordan
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Cancer Research Clinical Cancer Research
Cancer Epidemiology Biomarkers & Prevention Molecular Cancer Therapeutics
Molecular Cancer Research Cancer Prevention Research
Cancer Prevention Journals Portal Cancer Reviews Online
Annual Meeting Education Book Meeting Abstracts Online

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bouvet, M.
Right arrow Articles by Hoffman, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bouvet, M.
Right arrow Articles by Hoffman, R. M.
[Cancer Research 65, 9829-9833, November 1, 2005]
© 2005 American Association for Cancer Research


Cell and Tumor Biology

High Correlation of Whole-Body Red Fluorescent Protein Imaging and Magnetic Resonance Imaging on an Orthotopic Model of Pancreatic Cancer

Michael Bouvet1, Joseph Spernyak3, Matthew H. Katz1, Richard V. Mazurchuk3, Shinako Takimoto1, Ralph Bernacki3, Youcef M. Rustum3, Abdool R. Moossa1 and Robert M. Hoffman1,2

1 Department of Surgery, University of California at San Diego; 2 AntiCancer, Inc., San Diego, California; and 3 Roswell Park Cancer Institute, Buffalo, New York

Requests for reprints: Robert M. Hoffman, AntiCancer, Inc., 7917 Ostrow Street, San Diego, CA 92111. Phone: 858-654-2555; Fax: 858-268-4175; E-mail: all{at}anticancer.com.


    Abstract
 Top
 Abstract
 Introduction
 Materials and Methods
 Results and Discussion
 References
 
We have developed genetically fluorescent orthotopic models of human pancreatic cancer. In these models, noninvasive fluorescent protein imaging (FPI) of internal primary tumors and metastatic deposits has been carried out. Whole-body tumor images are easily and inexpensively obtained using FPI, permitting both detection and quantification of tumor load. In this study, we simultaneously compared single mice with a highly fluorescent, red fluorescent protein–expressing orthotopic pancreatic cancer xenografts with both FPI and high-resolution magnetic resonance imaging (MRI). Images were acquired at multiple time points after tumor implantation in the pancreas. Indwelling pancreatic primary tumors and metastatic foci were detected by both FPI and MRI. Moreover, a strong correlation existed between images taken with these two technologies. FPI permitted rapid, high-throughput imaging without the need for either anesthesia or contrast agents. Both FPI and MRI enabled accurate imaging of tumor growth and metastasis, although MRI enabled tissue structure to be visualized as well. FPI has high resolution and is exceedingly rapid with instant image capture. We suggest a complimentary role for these two imaging modalities.


    Introduction
 Top
 Abstract
 Introduction
 Materials and Methods
 Results and Discussion
 References
 
Small-animal imaging has been an area of intense worldwide development over the past 5 years. Because orthotopically implanted tumors grow deep within the animal, a noninvasive method must be employed to effectively and reliably image and monitor their growth and dissemination over time. A variety of such systems have been described, including traditional imaging modalities such as computed tomography, ultrasound, and magnetic resonance imaging (MRI), as well as newer modalities utilizing bioluminescence and fluorescence imaging.

The most information about the efficacy of a therapeutic intervention in animal models of cancer can be obtained when tumor growth and progression are sequentially monitored in a single animal over the entire course of treatment in real time. In this way, real-time qualitative and quantitative characterization of the pharmacologic effects of an agent on tumor growth can be determined. Both fluorescent protein imaging (FPI; refs. 13) and MRI (4) have shown their usefulness for such studies.

Our laboratories have been at the forefront of small-animal imaging of orthotopic models with FPI and MRI (1–4). Although both FPI and MRI have shown to be very useful for whole-body imaging of small animals, they have not been directly compared.

We have developed models of human tumors which express high levels of either green fluorescent protein (5) or red fluorescent protein (RFP; ref. 6). Using these models, it is possible to visualize internally growing tumors in the intact live animal by illumination with light of an appropriate excitation wavelength. We have shown the ability of MRI to provide three-dimensional visualization of tumor growth and metastasis in a nude-mouse liver-metastatic model enabling real-time analysis of tumor response to therapeutics (4).

Our experience with these two modalities has led us to believe that a combined imaging approach using both MRI and FPI can be highly effective in the study of the effects of novel therapeutics on small-animal models of human cancer. In this study, we used a fluorescent, highly metastatic, orthotopic model of human pancreatic cancer, MIA PaCa-2, which has been engineered to selectively express high levels of RFP cloned from the Discosoma sp. sea coral (68). Imaging of orthotopically implanted primary tumors and metastases in the same animals by both FPI and high-resolution MRI, at multiple time points after implantation, permitted a comparison of these two techniques. Our data suggest a complimentary role for these two imaging modalities in preclinical studies of cancer in orthotopic mouse models.


    Materials and Methods
 Top
 Abstract
 Introduction
 Materials and Methods
 Results and Discussion
 References
 
Cell line. The MIA-PaCa-2 human pancreatic cancer cell line was obtained from the American Type Culture Collection (Rockville, MD). Cells were maintained in DMEM media supplemented with 10% heat-inactivated fetal bovine serum and 1% penicillin and streptomycin (Life Technologies, Inc., Grand Island, NY). Cells were cultured at 37°C in a 5% CO2 incubator.

Red fluorescent protein retroviral transduction and selection of MIA-PaCa-2-RFP pancreatic cancer cells. The pDsRed-2 vector (Clontech Laboratories, Inc., Palo Alto, CA) was used to engineer MIA-PaCa-2 clones stably expressing RFP, as described previously (8). This vector expresses RFP and the neomycin resistance gene on the same bicistronic message. pDsRed-2 was produced in PT67 packaging cells. RFP transduction was initiated by incubating 20% confluent MIA-PaCa-2 cells with retroviral supernatants of the packaging cells and DMEM for 24 hours. Fresh medium was replenished at this time and cells were allowed to grow in the absence of retrovirus for 12 hours. This procedure was repeated until high levels of RFP expression, as determined using fluorescence microscopy, were achieved. Cells were then harvested by trypsin-EDTA and subcultured into selective medium that contained 200 µg/mL G418. The level of G418 was increased to 2,000 µg/mL stepwise. Clones expressing high levels of RFP were isolated with cloning cylinders as needed, and were amplified and transferred using conventional culture methods. High RFP-expression clones were isolated in the absence of G418 for 10 passages to select for stable expression of RFP in vivo.

Animals and animal care. Male nude mice (NCr-nu/nu) between 4 and 6 weeks of age were maintained in a barrier facility on HEPA-filtered racks. The animals were fed with autoclaved laboratory rodent diet (Teckland LM-485, Western Research Products, Orange, CA) and were maintained on a daily 12-hour light 12-hour dark cycle. Animal experiments were done in accordance with the Guidelines for the Care and Use of Laboratory Animals (NIH Publication no. 85-23) under assurance no. A3873-01 and were approved by the Institutional Animal Care and Use Committee at AntiCancer, Inc. (San Diego, CA) and Roswell Park Cancer Institute (Buffalo, NY).

Surgical orthotopic implantation of MIA-PaCa-2-RFP tumors. Red-fluorescent human pancreatic cancer xenografts were established in nude mice by surgical orthotopic implantation (9). Briefly, MIA-PaCa-2-RFP tumors in the exponential growth phase, grown s.c. in nude mice, were resected aseptically. Necrotic tissues were cut away, and the remaining healthy tumor tissues were cut with scissors and minced into 1 mm3 pieces in RPMI 1640. Mice were then anesthetized and their abdomens were sterilized with alcohol. An incision was then created through the left upper abdominal pararectal line and peritoneum. The pancreas was carefully exposed and two tumor pieces were transplanted onto the middle of the gland using a single 8-0 surgical suture (Davis-Geck, Inc., Manati, Puerto-Rico). The pancreas was then returned into the peritoneal cavity, and the abdominal wall and the skin were closed in two layers using 6-0 surgical sutures. All procedures were done with a 7x microscope (Olympus) or standard surgical loupes.

Fluorescence protein imaging. In vivo fluorescence imaging was done weekly. This was done in a fluorescent light box illuminated by fiberoptic lighting at 470 nm (Lightools Research, Encinitas, CA). Emitted fluorescence was collected through a long-pass filter GG475 (Chroma Technology, Battleboro, VT) on a Hamamatsu C5810 3-chip cooled color CCD camera (Hamamatsu Photonics Systems, Bridgewater, NJ). High-resolution images of 1,024 x 724 pixels were captured directly on an IBM PC or continuously through video output on a high-resolution Sony VCR model SLV-R1000 (Sony Corp., Tokyo, Japan). Images were processed for contrast and brightness and analyzed with the use of Image Pro Plus 3.1 software (Media Cybernetics, Silver Spring, MD). Real-time determination of tumor burden was done by quantifying fluorescent surface area, as described previously (5, 8).

Mice were also sacrificed and explored through a midline laparotomy and sternotomy. Excitation of RFP in the light box described above facilitated identification of primary and metastatic disease by fluorescence visualization. After acquiring full-body, open images, the solid organs were removed and their surfaces were thoroughly examined for any evidence of metastases through a Leica fluorescence stereo microscope model LZ12 (Leica Microsystems, Inc., Bannockburn, IL) equipped with a mercury 50 W lamp power supply. Selective excitation of RFP was produced through a D425/60 band-pass filter and 470 DCXR dichroic mirror. Emitted fluorescence was collected by the Hamamatsu camera system described above.

Magnetic resonance imaging. Following the acquisition of whole-body fluorescence images, full-body MRI acquisitions were done on a weekly basis. Before scanning, each animal was anesthetized with 4% isofluorane and then placed within a 3-mm-diameter butyrate plastic carrier tube. Body temperature was regulated by a small heating pad within the carrier containing circulating water at 37°C. Constant anesthesia was maintained with 2% isofluorane via an inlet tube. A small vacuum applied to a second tube served to remove carbon dioxide and excess anesthetic. In some animals, gadolinium-based contrast enhancing agent (Magnevist, Berlex, Inc., Montville, NJ) was injected into the dorsal tail vein at a concentration of 0.3 mmol/kg to improve contrast in T1-weighted images.

High-resolution MRI scans were done using a General Electric CSI 4.7 T/33 cm horizontal bore magnet (GE NMR Instruments, Fremont, CA) with radiofrequency and computer systems incorporating AVANCE digital electronics (Bruker BioSpec platform with ParaVision Version 2.1 Operating System, Bruker Medical, Billerica, MA).

MRI data were acquired using a G060 removable gradient coil insert generating a maximum field strength of 950 mT/m, and a custom-designed 35-mm radiofrequency transceiver coil. Standard spin-echo and rapid acquisition with relaxation enhancement MRI pulse sequences were used to acquire multislice images (4).

T1-weighted and T2-weighted coronal and transverse axial multislice, two-dimensional images were acquired for each mouse. T1-weighted spin-echo images were acquired with the following parameters: echo time/repetition time = 8/400 ms, number of excitations (averages) = 8. T2-weighted rapid acquisition with relaxation enhancement spin-echo images were acquired with the following parameters: echo time/repetition time = 40/2,750 ms, echo train length = 4, number of excitations = 8. T1- and T2-weighted images offer different but complementary contrast dependent on the different T1 and T2 relaxation rates within normal and malignant tissues. Using the imaging parameters outlined above, tumor and metastases appear hypointense (dark) on T1-weighted images and hyperintense (bright) on T2-weighted images.

Coronal images were acquired using a 256 x 192 acquisition matrix with 24 1-mm slices over a field of view of 4.8 x 3.2 cm. Axial images were acquired using a 192 x 192 acquisition matrix with 25 1-mm slices over a field of view of 3.2 x 3.2 cm.

Three-dimensional acquisitions were also acquired for a subset of animals to obtain isotropic voxels for volume rendering. Three-dimensional acquisitions were acquired with rapid acquisition with relaxation enhancement spin-echo sequences with acquisition parameters of echo time/repetition time = 28/750 ms, echo train length = 8, and number of excitations = 2. Image data were acquired using a 256 x 128 x 128 matrix over a field of view of 6.4 x 3.2 x 3.2 cm for an isotropic resolution of 250 µm per voxel.

Image analysis and three-dimensional volume rendering of MRI data were done using AnalyzePC Version 5.0 (Biomedical Imaging Resource, Mayo Foundation, Rochester, MN). Specifically, raw data from the magnetic resonance scanner were reformatted and displayed using AnalyzePC. Regions of interest (normal tissue, tan; tumor, red) were defined using seed-growing algorithms with manual adjustment on visual inspection. Tumor volumes were calculated by multiplying the number of tumor voxels by the individual voxel volume. Three-dimensional magnetic resonance data were rendered with two reflective ray-casting algorithms, volume-compositing and gradient shading with selective transparency, in AnalyzePC volume rendering tool (10). These algorithms were chosen to present contrasting views of tumor size and location. The gradient shading with transparency rendering allows for internal structures to be visualized regardless of depth, whereas the volume-composite rendering was chosen to simulate the attenuation of red fluorescent light emitting from tumors within the body. For volume-composite rendering, the {alpha} map, which defines color and transparency of voxels rendered based on voxel intensity value, was adjusted such that all voxels were rendered with an {alpha} value (opacity) = 0.05, allowing for portions of tumor near the surface of the animal to be visualized. For the gradient shading/transparency rendering, tumor and normal tissue were rendered with 50% opacity to allow for complete visualization of the tumor regardless of location within the animal.

Correlation of fluorescent protein imaging and magnetic resonance imaging measurements of tumor burden. To confirm a correlation between tumor burdens, as determined by externally visualized RFP fluorescence and MRI measurements of tumor volume, the primary tumor of each mouse was used. The externally visualized RFP fluorescent area and the tumor volume based on MRI were determined as described above. The correlation coefficient r was calculated between tumor volume and RFP fluorescence. P < 0.05 was considered significant.


    Results and Discussion
 Top
 Abstract
 Introduction
 Materials and Methods
 Results and Discussion
 References
 
Comparison of whole-body fluorescent protein imaging and magnetic resonance imaging of primary pancreatic tumors. Whole-body FPI and MRI allowed longitudinal visualization of pancreatic malignancy in an orthotopic nude mouse model. Figure 1 shows examples of such imaging by FPI and T1- and T2-weighted MRI. Contrast agent was administered i.v. before MRI on day 7 but not on day 10, accounting for tumor enhancement on T1-weighted images on day 7. The primary tumor was clearly visible using each imaging modality.



View larger version (70K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1. Visualization of primary pancreatic tumors in an orthotopic nude mouse model by FPI and T1- and T2-weighted MRI. A single mouse that underwent serial imaging of fluorescent MIA-PaCa-2-RFP human pancreatic tumor growth (see Materials and Methods for details). Contrast enhancing agent was administered i.v. before imaging on day 7 but not on day 10, accounting for enhanced contrast on T1-weighted images on day 7. Primary tumor was clearly visible using each imaging strategy. Arrows, tumor with MRI.

 
To determine whether the two imaging modalities correlated, 10 mice with tumors <1,500 mm3 were analyzed. Tumor volume as calculated by MRI and tumor area as calculated by FPI were compared (Fig. 2). The FPI image area correlated strongly with tumor volume measured by MRI for tumors <1,500 mm3 (R2 = 0.7035, P = 0.0024). For tumors <2,000 mm3, there was still a significant correlation (R2 = 0.3363, P = 0.0481; data not shown) although it was not as strong as for smaller tumors. For tumors >2,000 mm3, parts of the pancreatic tumor had grown close to the skin, which then overexposed the camera from picking up the portions of the tumor deeper inside the animal, thereby precluding correlation between the two modalities.



View larger version (11K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2. FPI area correlated strongly with tumor volume measured by MRI for tumors <1,500 mm3 (R2 = 0.7035, P = 0.0024). Measurement of externally visualized FPI and calculated measurements of the primary tumor by MRI of each mouse (n = 10) were obtained, as described in Materials and Methods.

 
Comparison of fluorescent protein imaging and magnetic resonance imaging of metastatic tumors. Figure 3 shows whole-body images of a mouse after surgical orthotopic implantation of MIA-PaCa-2-RFP human pancreatic cancer. Front and side views using FPI correlated well with front and side MRI volume-composite renderings. Front and side MRI transparency renderings identified all areas of the tumor.



View larger version (40K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3. Comparison of FPI and MRI of metastatic pancreatic cancer. Frontal (A) and transverse (B) views of a single nude mouse with orthotopically implanted MIA-PaCa-2-RFP human pancreatic cancer. Tumor is clearly visualized as red using both FPI and MRI. Left, transparency rendering provides qualitative analysis of total tumor burden. Right, volume rendering provides a depth of penetration perspective for comparison with FPI (center).

 
Figure 4 shows "open" views of a mouse with tumor visualized using direct FPI after opening the skin. Both open FPI and high-resolution T1- and T2-weighted high-resolution MRI could discern anatomic relationships between tumor and adjacent normal organs and tissues.



View larger version (79K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4. Comparison of MRI and FPI on metastatic pancreatic cancer. Imaging of primary and metastatic disease using FPI and MRI in nude mice 22 days after surgical orthotopic implantation. Whole-body FPI (A, side view; B, frontal view). Neither anesthesia nor contrast agents are necessary to provide highly specific, high-resolution images of indwelling abdominal tumors. FPI of a sacrificed, opened animal shows small, deep metastases that may be missed using whole-body imaging (C and D). Two-dimensional coronal MRI views of the same mouse (E, T1-weighted; F, T2-weighted) visualizes host organ anatomy as well as tumor. Three-dimensional reconstructions (G, front; H, side) were then obtained. As with whole-body FPI, MRI loses sensitivity in the visualization of small metastases such as those to portal or mesenteric lymph nodes. Thick arrow, primary tumor; PS, peritoneal surface metastasis; L, liver; H, stomach; S, spleen; D, diaphragmatic metastasis; M, mesenteric lymph node metastasis; PN, portal lymph node metastasis; RP, retroperitoneal disease.

 
Comparison of fluorescent protein imaging and magnetic resonance imaging on pancreatic tumors implanted on the liver. Because pancreatic cancer can often metastasize to the liver, we examined the role of MRI and FPI in mice with RFP-expressing MiaPaCa-2 implanted directly on the liver. Fragments of MiaPaCa-2 RFP pancreatic tumors were implanted into both lobes of the liver and then imaged 3 weeks later. Figure 5 shows that these liver tumors could be clearly visualized by both modalities.



View larger version (37K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 5. Comparison of MRI and FPI on pancreatic tumors explanted on the liver. MRI and FPI of a mouse 3 weeks after surgical orthotopic implantation of MiaPaCa-2 RFP pancreatic tumors into both lobes of the liver. A, adjacent, transverse axial sections using MRI show two large tumors outlined in yellow. Whole-body FPI of same mouse with front view (B), left view (C), and right view (D).

 
Comparison of magnetic resonance imaging and fluorescent protein imaging on ex vivo metastases. Comparison of whole-body MRI and FPI of ex vivo metastases was also carried out, as shown in Fig. 6. A T2-weighted, axial magnetic resonance image demonstrating left kidney metastasis was confirmed by FPI of a kidney metastasis ex vivo. A suspicious lesion in the liver on T2-weighted image was confirmed to be a metastatic tumor using FPI of the liver ex vivo.



View larger version (68K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 6. Comparison of MRI and ex vivo FPI. T2-weighted axial MRI (A) demonstrating left kidney metastasis, confirmed by FPI (B) of kidney ex vivo. Small, suspicious lesion in the liver on T2-weighted image (C) is easily confirmed to be a metastatic tumor using FPI (D) of the liver ex vivo.

 
General observations. Selective tumor fluorescence enabled acquisition of whole-body images in a noninvasive manner using simple, inexpensive fluorescence imaging equipment. Neither anesthesia nor contrast agents are necessary to provide highly specific, high-resolution images of indwelling abdominal tumors. Fluorescence imaging of sacrificed animals showed small, deep metastases that may be missed using whole-body FPI and MRI. MRI of the same mouse permitted more complete evaluation of tumor and host organ anatomy. Further visualization of the depth and size of the tumor was obtained via three-dimensional rendering of the magnetic resonance data. As with whole-body FPI, MRI lost sensitivity in the visualization of small metastases such as those to portal or mesenteric lymph nodes. In addition, use of MRI required anesthesia to immobilize the mouse during the long acquisition times.

Our study shows the combined utility of an imaging protocol that uses both FPI and MRI. Both modalities can be used to obtain serial, high-resolution images of tumor growth in the live animal over the course of a preclinical study. FPI may be done efficiently and inexpensively in the live animal without contrast enhancing agents or anesthesia. This modality has 100% specificity for tumor detection. MRI has the advantage that organ and tumor anatomy is well defined but its use requires significant cost and the use of anesthesia. Contrast enhancing agents may be used to increase tumor visibility and thereby increase specificity. FPI has the advantage of simplicity of equipment, lack of need of anesthesia or contrast agents, and high sensitivity. The high degree of correlation in whole-body imaging suggests that both modalities can be used in a complementary fashion for screening, quantifying tumor growth and assessing therapeutic efficacy in preclinical, small-animal research.


    Acknowledgments
 
Grant support: NIH grant R21 CA109949-01, American Cancer Society grant RSG-05-037-01-CCE (M. Bouvet), and National Cancer Institute grants CA099258, CA103563, and CA101600 (to AntiCancer, Inc.).

The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked advertisement in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

Received 5/ 6/05. Revised 7/ 7/05. Accepted 8/16/05.


    References
 Top
 Abstract
 Introduction
 Materials and Methods
 Results and Discussion
 References
 

  1. Yang M, Baranov E, Jiang P, et al. Whole-body optical imaging of green fluorescent protein-expressing tumors and metastases. Proc Natl Acad Sci U S A 2000;97:1206–11.[Abstract/Free Full Text]
  2. Hoffman RM. Green fluorescent protein imaging of tumour growth, metastasis, and angiogenesis in mouse models. Lancet Oncol 2002;3:546–56.[CrossRef][Medline]
  3. Yang M, Li L, Jiang P, Moossa AR, Penman S, Hoffman RM. Dual-color fluorescence imaging distinguishes tumor cells from induced host angiogenic vessels and stromal cells. Proc Natl Acad Sci U S A 2003;100:14259–62.[Abstract/Free Full Text]
  4. Wu M, Mazurchuk R, Chaudhary ND, et al. High-resolution magnetic resonance imaging of the efficacy of the cytosine analogue 1-[2-C-cyano-2-deoxy-ß-D-arabino-pentofuranosyl]-N(4)-palmitoyl cytosine (CS-682) in a liver-metastasis athymic nude mouse model. Cancer Res 2003;63:2477–82. [AN: 12750269].[Abstract/Free Full Text]
  5. Bouvet M, Wang J, Nardin SR, et al. Real-time optical imaging of primary tumor growth and multiple metastatic events in a pancreatic cancer orthotopic model. Cancer Res 2002;62:1534–40.[Abstract/Free Full Text]
  6. Katz MH, Takimoto S, Spivack D, Moossa AR, Hoffman RM, Bouvet M. An imageable highly metastatic orthotopic red fluorescent protein model of pancreatic cancer. Clin Exp Metastasis 2004;21:7–12.[Medline]
  7. Matz MV, Fradkov AF, Labas YA, et al. Fluorescent proteins from nonbioluminescent Anthozoa species. Nat Biotechnol 1999;17:969–73. [AN: 10504696].[CrossRef][Medline]
  8. Katz MH, Takimoto S, Spivack D, Moossa AR, Hoffman RM, Bouvet M. A novel red fluorescent protein orthotopic pancreatic cancer model for the preclinical evaluation of chemotherapeutics. J Surg Res 2003;113:151–60. [AN: 12943825].[CrossRef][Medline]
  9. Fu X, Guadagni F, Hoffman RM. A metastatic nude-mouse model of human pancreatic cancer constructed orthotopically with histologically intact patient specimens. Proc Natl Acad Sci U S A 1992;89:5645–9. [AN: 1608975].[Abstract/Free Full Text]
  10. Robb RA. 3D visualization in biomedical applications. Annu Rev Biomed Eng 1999;1:377–99.[Medline]



This article has been cited by other articles:


Home page
Cancer Res.Home page
T. Shimamura, R. E. Royal, M. Kioi, A. Nakajima, S. R. Husain, and R. K. Puri
Interleukin-4 Cytotoxin Therapy Synergizes with Gemcitabine in a Mouse Model of Pancreatic Ductal Adenocarcinoma
Cancer Res., October 15, 2007; 67(20): 9903 - 9912.
[Abstract] [Full Text] [PDF]


Home page
Mol. Cell. Biol.Home page
T. B. Deramaudt, M. Takaoka, R. Upadhyay, M. J. Bowser, J. Porter, A. Lee, B. Rhoades, C. N. Johnstone, R. Weissleder, S. R. Hingorani, et al.
N-Cadherin and Keratinocyte Growth Factor Receptor Mediate the Functional Interplay between Ki-RASG12V and p53V143A in Promoting Pancreatic Cell Migration, Invasion, and Tissue Architecture Disruption.
Mol. Cell. Biol., June 1, 2006; 26(11): 4185 - 4200.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bouvet, M.
Right arrow Articles by Hoffman, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bouvet, M.
Right arrow Articles by Hoffman, R. M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Cancer Research Clinical Cancer Research
Cancer Epidemiology Biomarkers & Prevention Molecular Cancer Therapeutics
Molecular Cancer Research Cancer Prevention Research
Cancer Prevention Journals Portal Cancer Reviews Online
Annual Meeting Education Book Meeting Abstracts Online