| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Cell, Tumor, and Stem Cell Biology |
Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, Bethesda, Maryland
Requests for reprints: Murali C. Krishna, Building 10, Room B3B69, NIH, Bethesda, MD 20892-1002. Phone: 301-496-7511; Fax: 301-480-2238; E-mail: murali{at}helix.nih.gov.
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
Cellular energy is derived from the transport of electrons through a series of oxidation reactions to inspired molecular oxygen, resulting in an overall reducing environment. Several redox couples exist in cells contributing to the overall redox status (7). GSH, NADH, and NADPH are a few examples of intracellular molecules, which, in coordination with the corresponding enzymatic cycles, collectively determine the global redox status of tissue (7). These redox couples are responsive to changes in oxidizing-reducing conditions which can result from changes in blood flow, oxygenation, and other variables (8, 9). Many of the biochemical mechanisms that underlie the observed metabolic differences between malignant and normal tissue are well understood, making it possible to profile tissues based on the relative levels of key metabolites (4).
Noninvasive imaging modalities capable of detecting the levels of individual molecules related to cellular metabolism can potentially provide diagnostic and prognostic information. Localized phosphorus-31 magnetic resonance spectroscopy (31P-MRS) has been successfully used to distinguish malignant tissue from benign tissue by monitoring levels of endogenous organic and inorganic phosphates indicative of the energetic status (3, 10). MRS imaging (MRSI) techniques, detecting 1H chemical shifts of endogenous intracellular molecules such as choline and citrate, have an advantage over 31P-MRS in terms of sensitivity and the capability to image. However, for both MRS and MRSI, the low levels of the metabolites being monitored may impose a limitation on the temporal and spatial resolutions.
In addition to biochemical differences from normal tissue, several, but not all, solid tumors exhibit hypoxic regions resulting from inadequate vasculature and/or compromised blood flow (11). These tumors, although exhibiting radiation resistance because of hypoxia, might be selectively sensitized by hypoxic cell cytotoxins (12). Thus, techniques that noninvasively distinguish biochemical/physiologic differences can provide a means to characterize malignant tissue with specificity and sensitivity. Radioactive tracers are also useful in providing functional/biochemical information in imaging modalities. The uptake and retention of the radiotracer 18-fluorodeoxyglucose in tumors is monitored by positron emission tomography imaging to differentiate benign lesions from malignant lesions (13, 14).
More recently, dynamic contrastenhanced magnetic resonance imaging (MRI) is being successfully applied to identify tumors using T1 contrast agents such as Gd3+ complexes, which provide enhancement to MR images (1517). This technique uses perfusion differences between benign and malignant tissue and therefore examines extracellular differences in tumor vasculature based on the characteristic time-intensity profiles (18). Because the contrast agent enhances the water/protonbased image intensity, temporal and spatial resolutions tend to be much better compared to MRSI. The image intensity monitored as a function of time with dynamic contrastenhanced MRI after injecting the contrast agent provides information of the perfusion and clearance of the contrast agent. However, Gd3+ is biologically "redox-inert" and any time-dependent loss in contrast is solely by clearance, which is an advantage in perfusion studies. Because of their size, the Gd3+ complexes are restricted to extracellular regions and do not provide contrast from intracellular regions.
Nitroxides are stable organic free radicals having a single unpaired electron and are therefore capable of providing image contrast via shortening T1 similar to Gd3+ complexes (19, 20). Although nitroxides compare unfavorably to conventional T1 contrast agents such as Gd3+ complexes in terms of relaxivity, being cell permeable, their volume distribution is significantly greater (21, 22). This partially compensates for their lower relaxivity compared with the cell-impermeable gadolinium complexes and provides useful T1 contrast enhancement per unit volume similar to unchelated Mn2+ (23).
Nitroxides were initially evaluated as potential contrast agents in MRI and were found suboptimal in the 1980s because of their lower molar relaxivity compared with Gd3+ (19). In addition, the rapid bioreduction of the paramagnetic nitroxide to the corresponding diamagnetic hydroxylamine compromised their utility as contrast agents (24). However, their propensity to undergo bioreduction might provide useful information pertaining to tissue redox status, provided that sufficient contrast enhancement is available initially (25).
Nitroxides are redox-active species which can be oxidized or reduced by the corresponding reactants in cells (26). Nitroxides were shown to undergo oxidation to the corresponding oxoammonium by various oxidants such as hypervalent heme, HO2·, CO3·, and NO2· radicals (2730). Thus, in tumors, low levels of oxidative stress may generate these species, which can decrease the nitroxide levels faster than in normal tissue. Oxoammonium cations can be reduced to the nitroxide level by superoxide at diffusion-limited rates. Nitroxides can also be reduced to the corresponding hydroxylamines by reductants such as ascorbate, semiquinone radical, and also by intercepting reducing equivalents from the electron transport chain. The hydroxylamines, on the other hand, can be oxidized to the nitroxides in the presence of hydrogen peroxide and other oxidants such as transition metal complexes (31).
In cell culture experiments, nitroxides were found to undergo accelerated conversion to hydroxylamines under hypoxic conditions compared with normoxia (32). Furthermore, in normoxic cells, the conversion was significantly retarded when the thiol levels were depleted or in cells deficient in the enzyme glucose-6-phosphate dehydrogenase (9, 33). In in vivo studies, irrespective of whether nitroxide or hydroxylamine is administered, the ratio of the nitroxide/hydroxylamine is constant and depends on the redox status of the tissue (9, 34, 35). These observations suggest that nitroxides participate in cellular redox reactions and that their levels may be indicative of the global cellular redox status. Nitroxides also offer structural flexibility in that there are numerous derivatives available that can be directed to localize in specific subcellular compartments or be restricted to extracellular spaces (22, 36).
Earlier studies have shown that a cell-permeable nitroxide was reduced faster in tumor than in normal tissue (8, 9, 37). Therefore, monitoring the rate of transformation of suitable nitroxides to the corresponding diamagnetic species using MRI can provide in vivo assessment of redox status in a noninvasive manner. In this study, the structural determinants on the nitroxide ring influencing the reduction rates and their differences between tumor and normal tissue were investigated.
| Materials and Methods |
|---|
|
|
|---|
Animal Studies
Female C3H mice were supplied by the Frederick Cancer Research Center, Animal Production (Frederick, MD). The mice were 6 to 8 weeks of age at the time of experimentation, weighing 20 to 30 g, and were housed, five per cage, in climate-controlled, circadian rhythmadjusted rooms, and were allowed food and water ad libitum. All in vivo experiments were carried out in compliance with the Guide for the Care and Use of Laboratory Animal Resources (1996), National Research Council, and approved by the National Cancer Institute Animal Care and Use Committee. Tumor cells were injected s.c. as a single cell suspension of 106 squamous cell carcinoma (SCCVII) cells in the right hind leg. The tumors grew to a diameter of 1.5 cm (1,800 mm3) in
10 days, at which time, all imaging experiments were carried out.
MRI and Pulse Sequence
MRI measurements were done with a 4.7 T scanner controlled with ParaVision 3.0.1 (Bruker BioSpin MRI GmbH, Rheinstetten, Germany). For T2 mapping, spin echo images were obtained using a multi-slice multi-echo (MSME) sequence with a 10-echo train and an echo time of 15 ms. The scan time for a T2 mapping image set (NEX = 1) by the MSME sequence was 10 minutes. Spoiled gradient echo (SPGR; also referred to as gradient echo fast imaging: repetition time (TR), 75 ms; echo time (TE), 3 ms; flip angle (FA), 45 degrees; NEX, 2) was employed to observe the T1 effect. The scan time for six slices with the SPGR sequence was 20 seconds. Other common image variables are as follows: image resolution was 256 x 256, field of view (FOV) was 7.0 x 7.0 cm, slice thickness was 2.0 mm.
"Redox phantom". Five phantom tubes were prepared as shown in Fig. 1B . Tube (i) contained PBS in the absence of Tempol. Tubes (ii), (iii), (iv), and (v) contained 2 mmol/L of Tempol in the presence of 0, 0.5, 1, and 2 mmol/L of ascorbic acid (AsA), respectively, and were horizontally set in the resonator. After the addition of the AsA/PBS (pH 7.4) solution using a SP-10 catheter from a syringe, the MRI measurement with SPGR was immediately started and continuously measured for up to 10 minutes. The experiments were repeated four times with freshly prepared solutions. Semilogarithmic plots of the time course of MRI signal change in the region of interest (ROI, 30 x 30 pixels) were used for decay rate calculation. The decay rates of tubes (iii), (iv), and (v) were calculated by using filled symbols (Fig. 1C). The MRI conditions used were as follows: TR, 75 ms; TE, 3 ms; FA, 45 degrees; NEX, 2; scan time, 20 seconds. Image resolution, 256 x 256; FOV was 3.2 x 3.2 cm; slice thickness was 2.0 mm.
|
In vivo MRI Experiments
Mice were anesthetized by isoflurane (1.5%) in medical air (700 mL/min) and secured on a special holder by adhesive skin tape, stomach-side down. A breathing sensor (SA Instruments, Inc., Stony Brook, NY) was placed on the back of the mice. A nonmagnetic temperature probe (FISO, Quebec, Canada) was used to monitor the rectal temperature of the mice. The tail vein was cannulated for the injection of contrast agent. The mouse was then placed in the resonator, which was previously warmed up using a hot water cycling pad. The resonator unit, including the mouse, was placed in the magnet bore. The MR measurements were started after the mouse's core body temperature stabilized to 37°C. The mouse body temperature was kept at 37 ± 1°C during the experiment. Before taking the measurements with the nitroxide contrast agents, native images of the mouse were taken with the variables mentioned above. The middle two slices including normal tissue, tumor tissue, kidney, and artery area, were selected as reference for calculating signal enhancement in the presence of the nitroxide agents. T1-weighted images were acquired continuously for 20 minutes, using SPGR. A solution of nitroxide contrast agent in PBS (1.5 µmol/g body weight) was injected via tail vein cannulation, 2 minutes after starting the scan.
Image Analysis
The MRI data were analyzed using the ImageJ software package.1 T2 maps were calculated using a plug-in (MRI analysis calculator, Karl Schmidt, HypX Laboratory, Brigham and Women's Hospital) available in ImageJ.
Total Tissue Nitroxide Concentration Assessment
Nitroxide contrast agents dissolved in PBS (pH 7.4) were injected into the tail vein of C3H mice bearing SCCVII tumors at a dose of 1.5 µmol/g body weight. The concentration in the bolus was 150 mmol/L for 3CxP and 300 mmol/L for Tempol and 3CP (three animals each). The blood and organs were collected and wet weight was determined at different times (2.5, 5, 7.5, 10, 15, and 20 minutes). Blood samples were diluted and tissue samples were homogenized with 4-fold volumes of PBS. Ferricyanide (200 µL of 10 mmol/L solution) was added to each sample solution (800 µL) to obtain the final concentration of 2 mmol/L. The ferricyanide quantitatively converts the hydroxylamine produced as a result of in vivo reduction back to the oxidized form (2729). The signal intensities of the 100 µL samples were measured using a Varian E-9 X-band EPR spectrometer. The EPR spectrometer operating conditions were: modulation frequency, 100 kHz; microwave power, 1 mW. Because there is linearity up to 2 mmol/L between the concentration and EPR signal magnitude of nitroxide contrast agents (data not shown), EPR signal magnitudes of homogenate mixtures were converted to the concentration using previously obtained standard curves (100 µmol/L-2 mmol/L). Finally, nitroxide concentrations in the tissues were calculated based on a dilution factor of 4.
Statistical Analyses
The statistical differences were estimated with the TTEST function in Microsoft Excel XP. The suitable "type" and "tail" for the test was selected according to the correspondence and variance of the data. Significances were estimated at P < 0.05.
| Results |
|---|
|
|
|---|
0.2 mmol/L1 s1. Phantom experiments were carried out to examine the capability of Tempol to participate in redox reactions and elicit time-dependent changes in image contrast using AsA as a model reductant, which can convert the paramagnetic nitroxide molecule to the corresponding diamagnetic hydroxylamine (Fig. 1A). Figure 1B (left) shows the schematics of the five-tube phantom used. Tube (i) is a PBS solution with no additives. Tubes (ii), (iii), (iv), and (v) contained 2 mmol/L of Tempol in the presence of 0, 0.5, 1, and 2 mmol/L AsA, respectively. T1-weighted MRI images were collected using the SPGR sequence at different times after the reaction was initiated. As expected, no enhancement in intensity was observed in tube (i), in which Tempol was not included. In tube (ii), which contained 2 mmol/L of Tempol, a significant enhancement in image intensity was noted, which did not change with time, consistent with the notion that no reduction reaction takes place in the absence of AsA. However, in tubes (iii), (iv), and (v), which contained AsA and Tempol, a time-dependent loss in image intensity was noticed. The rate at which the intensity decreased in these tubes was dependent on AsA concentration. Tube (v), which contained Tempol in the presence of 2 mmol/L of AsA, exhibited a loss in intensity characterized by a rate constant of k = 0.33 ± 0.03 min1, whereas tubes (iii) and (iv), which had 0.5 or 1 mmol/L of AsA, exhibited a reduction constant rate of k = 0.07 ± 0.02 min1 and k = 0.18 ± 0.03 min1, respectively, suggesting that the reduction rate was directly dependent on the concentration of the reductant (Fig. 1C). To compare the decay rate between EPRI and MRI, 3CP and AsA (5 and 10 mmol/L) phantoms were prepared. The decay rate constants, obtained using both modalities, were similar (5 mmol/L of AsA: EPRI, 0.066 ± 0.004 min1; MRI, 0.007 ± 0.007 min1; 10 mmol/L of AsA: EPRI, 0.136 ± 0.009 min1; MRI, 0.130 ± 0.006 min1) and changed as a function of AsA concentration (Table 1
). These results show that MRI decay rates can validly extract the reduction rates of 3CP to hydroxylamine as well as EPRI. The in vivo data with 3CP using MRI also showed that MR signal change between normal and tumor tissue was similar to EPRI (Table 1; ref. 25).
|
|
|
3.5 times that observed in the normal tissue. For 3CP, the decay rate in the tumor was
2 times higher than in the normal leg. However, in the case of the cell-impermeable nitroxide, 3CxP, no significant differences in signal decay rates between tumor and muscle tissue were detected. When the signal decay rates of the three nitroxides in the normal leg were compared, they ranked, from fastest to slowest (Tempol >> 3CP > 3CxP). The levels of nitroxide + hydroxylamine as a function of time after i.v. administration of the three nitroxides were examined by analyzing the tissue extracts after oxidation with ferricyanide using EPR spectroscopy. The results of EPR analysis are summarized in Fig. 4
. Although Figs. 2 and 3 show that MR image intensity decays in both tumor and normal muscle, the total (nitroxide + hydroxylamine) does not change significantly during the imaging time in either tumor or muscle. Furthermore, similar patterns were observed in blood and kidney levels in which the MR intensity exhibited a rapid decay as a function of time, whereas the total levels remained unchanged. It was suggested that the decrease in image intensity observed in T1-weighted imaging is associated with the bioreduction of nitroxides predominantly in the imaging time windows. Furthermore, the contributions of clearance of nitroxide to the observed intensity decay rates were minimal. Intracellular reducing equivalents and electrons intercepted from the mitochondrial electron transport chain were proposed as the mechanisms which underlie the reduction of nitroxides (32, 39).
|
|
| Discussion |
|---|
|
|
|---|
MRI-based techniques such as MRS and MRSI can detect levels of endogenous metabolites that reflect the tissue redox status (1). These techniques, which have been shown to be of significant diagnostic value, were used to successfully monitor treatment progress (5, 42). However, the low levels of the metabolites impose limitations on the resolution (temporal and spatial) achievable with MRS and MRSI. Paramagnetic contrast agents in MRI provide information on tumor perfusion (16). However, clinically used contrast agents are extracellular, do not participate in redox reactions, and are therefore insensitive to tissue redox status.
Nitroxides have a combination of unique properties that make them promising candidates as redox statussensitive MRI contrast agents. The paramagnetic nitroxide radicals can undergo reduction to the corresponding diamagnetic hydroxylamine, which can revert to the nitroxide in the presence of oxidants or if the cellular oxygen status permits (27, 31). The nitroxide reduction is supported by intracellular enzymatic processes, and is more efficient in hypoxic cells than in aerobic cells (43, 44). They are also effective antioxidants, which offer protection to cells in culture and were used successfully in animals exposed to diverse types of oxidative insult (26). Earlier studies established the feasibility of using MRI to monitor the spatial distribution of nitroxides and their redox transformations in vivo with high spatial and temporal resolution (25).
Several studies showed that thiol-dependent processes contribute, at least in part, to in vivo nitroxide reduction (9, 45). Earlier studies using EPR spectroscopy in cellular incubations of nitroxides, the cell-permeable nitroxides, Tempol and 3CP, were found to accumulate intracellularly, whereas 3CxP was not detectable from intracellular regions even after prolonged incubations. However, anionic transport pathways for 3CxP cannot be ruled out. Additionally, the accumulation of nitroxides in extracellular spaces as a result of leaky vasculature may make the clearance pathways of nitroxides less efficient. In this study, an established EPR method of invasively detecting total nitroxide/hydroxylamine levels was used to show that SPGR MRI signal intensity loss, after nitroxide injection, is not due to washout. The combination of the nitroxide contrast agent and SPGR MRI studies provided us with pharmacokinetic information for various tissues. The availability of anatomic information, as well as the superior spatial and temporal resolution, make MRI more efficient at monitoring the pharmacokinetic properties of nitroxides compared with EPR imaging methods.
The MRI studies clearly show that among the nitroxides tested, the six-membered piperidine nitroxide, Tempol, was reduced rapidly compared with the two five-membered pyrrolidine nitroxides, 3CP and 3CxP. Tempol and 3CP (both cell permeable) were reduced in tumors more rapidly than in normal muscle. However, the cell-impermeable nitroxide, 3CxP, exhibited no difference between tumor and normal tissue. To determine the contribution of clearance processes to the time-dependent signal intensity loss in MRI experiments, ex vivo EPR analyses of tissues from an independent set of animals were done. EPR studies show that during the scan time of 20 minutes, the total (nitroxide + hydroxylamine) levels remained unchanged, suggesting that clearance is not a major contributor to the observed time-dependent intensity change. Importantly, the data further indicates that the observed time-dependent disappearance of MR image intensity enhancement due to Tempol and 3CP (both cell permeable) in various tissues occurred as a result of intracellular reduction.
| Conclusion |
|---|
|
|
|---|
| Acknowledgments |
|---|
| Footnotes |
|---|
Received 3/14/06. Revised 7/25/06. Accepted 8/14/06.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
C. S. Wilcox and A. Pearlman Chemistry and Antihypertensive Effects of Tempol and Other Nitroxides Pharmacol. Rev., December 1, 2008; 60(4): 418 - 469. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C. Ghosh, W.-H. Tong, D. Zhang, H. Ollivierre-Wilson, A. Singh, M. C. Krishna, J. B. Mitchell, and T. A. Rouault Tempol-mediated activation of latent iron regulatory protein activity prevents symptoms of neurodegenerative disease in IRP2 knockout mice PNAS, August 19, 2008; 105(33): 12028 - 12033. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. P. Cotrim, F. Hyodo, K.-I. Matsumoto, A. L. Sowers, J. A. Cook, B. J. Baum, M. C. Krishna, and J. B. Mitchell Differential Radiation Protection of Salivary Glands versus Tumor by Tempol with Accompanying Tissue Assessment of Tempol by Magnetic Resonance Imaging Clin. Cancer Res., August 15, 2007; 13(16): 4928 - 4933. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Cancer Research | Clinical Cancer Research |
| Cancer Epidemiology Biomarkers & Prevention | Molecular Cancer Therapeutics |
| Molecular Cancer Research | Cancer Prevention Research |
| Cancer Prevention Journals Portal | Cancer Reviews Online |
| Annual Meeting Education Book | Meeting Abstracts Online |